DEC200 Digital Ophthalmoscope Camera System

Ophthalmic visualisation using an ophthalmoscope camera system allows the clinician to visualise and capture images of the fundus and optic nerve by using both LED and infrared (IR) LED light for alignment and easily capturing images without the need for dilation.

Enables non-mydriatic fundus examinations with reflection-free imaging and a wide field of view to capture the appearance of optic disc, macula and retinal vasculature.

Non-mydriatic fundus photography

effective alternative to direct ophthalmoscopy for examining the ocular fundus in non-ophthalmology or remote settings.

DEC 200 Digital Ophthalmoscope Camera System is a simple-to-use, revolutionary non-mydriatic fundus camera.

  • Improves accessibility of retinal screening programmes
  • Makes use of the retina’s reflective properties to show details
  • No need for pupil dilation in the majority of cases
  • Painless for patients
  • Wide angle of the targeted retina
  • Cost-effective fundus image capture
  • Early diagnosis of macular degeneration, glaucoma, high blood pressure, damage caused by multiple sclerosis, diabetic retinopathy and other eye health conditions

Image gallery

Riester Ophthalmoscope Camera 02 Photo

3.5” screen allows for intuitive user interface with clear image capturing and reviewing without compromising on the mobility

Riester Ophthalmoscope Camera 05 Photo

7x internal fixation points cover a larger retina area and enable the patient to fix where to look

1-ophthalmic-camera-480x320-crop-1

DEC200 Digital Ophthalmoscope Camera System

Features and benefits

  • Simple operation
  • Images shared USB connection for easy transfer
  • 3.5” LCD touch panel for easy visualisation
  • LED illumination for clear clear imaging
  • Reflection-free images
  • Both auto-focus and power-focus function to facilitate image capturing
  • 7 internal fixation targets for macula center, disk center and peripheral image in DEC 200
  • Optical modules
  • Infrared and White LEDs for image targeting and capturing
  • Not necessary to dilate pupils
  • Non-mydriatic
  • 45 degree FOV of fundus image
  • 5 MP resolution
Ideal for telemedicine activities and mobile care
Providing access to ophthalmic consultative services in underserved areas

Seamlessly integrates with Riester’s Telemedicine stations and Telemedicine software solution partner

DocsinClouds

The TeleDoc software allows doctors to remotely provide their patients with quality care anywhere at any anytime. The software offers video consultation between doctor and patient, along with live transfer of patient vital signs, ECG, ultrasound, stethoscope amongst other medical data, giving doctors the capability to provide quality diagnosis, treatment, and monitoring of patient conditions. More about DocsinClouds Software.

Simultaneously capture and share live images and videos in the Riester Telemedicine Stations integrated into DocsinClouds telemedicine.

DocsinClouds
Riester Telemedicine case Photo New USB
Telemedicine Case

The Riester Telemedicine case is designed to allow patient assessments to be carried out in remote locations globally.

Riester Telemedicine Cart 04 Photo web
Telemedicine Cart

The Riester Telemedicine cart is designed specifically to deliver a stable platform for teleconsultations.

Product details

 

Control Unit
Focus Auto & manual focus
Picture Resolution 2560 x 1920 pixels
Video Resolution 2560 x 1920 pixels
LCD Monitor 3.5“ TFT LCD
Image Format JPEG (Photograph) and H.264 (Video)
Interface Mini USB 2.0, Micro HDMI (1.4), Wi-Fi (2.4 G)
File Transfer Mini USB Port to PC with USB cable 1.5 m (shielded)
Dynamic Video Output HDMI output with A-D HDMI cable 2.0 m (shielded)
USB live video enable from USB port with USB cable 1.5 m (shielded)
File Storage Memory card, supports 2 GB to 32 GB by FAT32 format
Dimension (L) 202.5 x (W) 89 x (H) 88 mm
Weight 295 g
Power Source Rechargeable Lithium Battery 3.6 V / Capacity 3350 mAh
Operating Time Standby mode: 6 hours
Operating mode: 1.5 - 4.5 hours (depend on optical lens used)

 

Fundus camera
View Angle 45 degrees (typical)
Diopter -20 to +20 D (typical)
Dimension 20.1 x 9 x 20.3 cm (typical)
Weight 450 g (typical)
Search Fundus Lighting Two modes: Natural white light-emitting diode (LED) or infrared LED.
Green LED for fixation
Camera / video flash light  Natural white LED



Ordering information

DEC200 Digital Eye Fundus Camera

ART. NO. REGION DESCRIPTION
1923 All except US DEC 200 Digital Ophthalmoscope Camera System



Downloads

Related products

riester-rcs-100-pack-02-photo-1408x-500x500-crop-1-2-1
RCS-100 Medical Camera System

RCS-100 Digital Camera System is available with a choice of lenses and adapters.

all-pupil-ii-2a-500x500-crop-1
All Pupil II Indirect Ophthalmoscope

Offers high-contrast, clear images with the world’s leading Keeler optics.

ri-scope-l-ophthalmoscope-front-back-500x500-crop-1-2
ri-scope® L Ophthalmoscope

Our ri-scope® L line of ophthalmoscopes contains our premium ophthalmoscopes options.

Where to buy?

Riester products are available in over 150 countries. Enter your country to easily find an authorized Riester distributor near you.