RCS-100 Digital Otoscope
The RCS-100 Medical Camera System with otoscope lens and LED light provides an enhanced view of the auditory canal, as well as 6x magnification displayed on the 5” LCD screen.
This is a real image of a healthy ear canal.
RCS-100 with otoscope lens can substitute the traditional otoscope
RCS-100 with otoscope lens can substitute or replace the traditional otoscope, providing the additional benefit of capturing and sharing the digital photograph or video of the ear canal and tympanic membrane. The otoscope lens can be used with a choice of reusable or disposable specula.
Photographic images of tympanic membranes in routine clinical practice
ENT & Audiology News notes: The ability to capture and record photographic images of tympanic membranes in routine clinical practice has several distinct advantages over hand-drawn representations. Photographs are helpful when explaining unfamiliar concepts to patients and can be a valuable aid when discussing treatment options. Photo documentation is essential for accurately monitoring evolving pathologies, such as tympanic membrane retraction, where subtle changes over time could be easily missed or overlooked when relying on drawings alone. Finally, photographs also provide a precise, contemporaneous record for medico-legal purposes.1
Product details
RCS-100 Otoscope Lens |
---|
Dimensions | 73.5 mm x 40.0 mm x 40.0 mm |
Weight | 96 g (3.39 oz) |
F/# (focal length/width) | 2.9 |
Max object distance | 15 mm, at max object distance FOC diameter: 15 mm |
Depth of field scope | 10 mm |
Lighting source | Natural light LED |
LED colour temperance | 4000 k |
Disposable and reusable specula | 2 mm (0.08 in), 3 mm (0.12 in), 4 mm (0.16 in), 5mm (0.2 in) |
RCS-100 |
---|
Size | 225 mm x 135 mm x 45 mm |
Weight | 292.0 g |
Focus | Automatic / Manual |
Image format | JPEG |
Video format | MP4 |
Adapt input | 100 - 240 VAC, 50/60 Hz, 0.3 A |
Adapt outnput | 5 VDC, 2 A |
USB | OTG and type-C USB |
Extend memory (OPT) | 16 GB Wi-Fi SD card |
RAM | 2 GB LPDDR3 |
ROM | 16 GB |
CMOS sensor resolution | Total number of pixels: 3296 (H) x 2512 (V) approx. 8.28 M pixels Number of effective pixels: 3296 (H) x 2480 (V) approx. 8.17 M pixels Number of active pixels: 3280 (H) x 2464 (V) approx. 8.08 M pixels |
Battery | 3.6 V, 2600 mAH, 18650 Li-ion battery Video 3.5 hours (fully charged battery at 25 °C ambient temperature) |
Ordering information
RCS-100
ART. NO. | REGION | DESCRIPTION |
---|---|---|
1970-H | All | RCS-100 basic model, no lenses |
1970-HXXO 1 | All except US | RCS-100 basic model, otoscope lens |
1970-HDGO | All | RCS-100 basic model, otoscope, dermatoscope and general lens |
1970-HXGO | All except US | RCS-100 basic model, otoscope and general lens |
1970-HDXO | All except US | RCS-100 basic model, dermatoscope and otoscope lens |
1 USA: Art. 1970-H + 13272
Lenses and Adapters
ART. NO. | REGION | DESCRIPTION |
---|---|---|
13272 | All | Otoscope lens |
Accessories
ART. NO. | REGION | DESCRIPTION |
---|---|---|
13274 | All except US | Case for RCS-100, black |
Otoscope lens specula
ART. NO. | REGION | DESCRIPTION |
---|---|---|
10800-532 | All | Reusable ear specula Ø 2.0 mm, pack of 10 pcs. |
10800-533 | All | Reusable ear specula Ø 3.0 mm, pack of 10 pcs. |
10800-534 | All | Reusable ear specula Ø 4.0 mm, pack of 10 pcs. |
10800-535 | All | Reusable ear specula Ø 5.0 mm, pack of 10 pcs. |
10801-532 | All except US | Disposable ear specula Ø 2.0 mm, pack of 100 pcs. |
10801-533 | All except US | Disposable ear specula Ø 3.0 mm, pack of 100 pcs. |
10801-534 | All except US | Disposable ear specula Ø 4.0 mm, pack of 100 pcs. |
10801-535 | All except US | Disposable ear specula Ø 5.0 mm, pack of 100 pcs. |
10802-532 | All except US | Disposable ear specula Ø 2.0 mm, pack of 500 pcs. |
10802-533 | All except US | Disposable ear specula Ø 3.0 mm, pack of 500 pcs. |
10802-534 | All except US | Disposable ear specula Ø 4.0 mm, pack of 500 pcs. |
10802-535 | All except US | Disposable ear specula Ø 5.0 mm, pack of 500 pcs. |
10803-532 | All | Disposable ear specula Ø 2.0 mm, pack of 1000 pcs. |
10803-533 | All | Disposable ear specula Ø 3.0 mm, pack of 1000 pcs. |
10803-534 | All | Disposable ear specula Ø 4.0 mm, pack of 1000 pcs. |
10803-535 | All | Disposable ear specula Ø 5.0 mm, pack of 1000 pcs. |
Downloads
The RCS-100 Medical Camera System
Learn more about the RCS-100 with a choice of lenses and adapters that can be used to assess a patient's eyes, ears, nose, throat, skin and more.

RCS-100 Medical Camera System
RCS-100 Medical Camera System is available with a choice of lenses and adapters.

RCS-100 with General Lens
RCS-100 Medical Camera System with General Lens can be utilised for a general initial screening.

RCS-100 Digital Dermatoscope
RCS-100 Medical Camera System with a Special Lens for digital dermoscopy.

RCS-100 with Endoscope Adapters
RCS-100 Medical Camera System with two different Endoscope Adapters.
Telemedicine
Telemedicine uses advanced telecommunication technologies to exchange health information and provide health care services across geographic, time, social, and cultural barriers.2 Our Telemedicine cart can include RCS-100 medical camera system as an optional module.

ENT & Audiology News, Vol 27, ISSUE 3 Jul/Aug. 2018 [accessed 13 April 2022].

Myers MR. Telemedicine: an emerging health care technology. Health Care Manag (Frederick). 2003 Jul-Sep;22(3):219-23. doi: 10.1097/00126450-200307000-00005. PMID: 12956223.