Diagnostic Instruments (EENT)

Reasons to Consider Having Your Own Diagnostic Kit

While diagnostic kits are commonly found in clinic rooms, it is essential for medical students to possess their own sets for various important reasons. Hospital rooms and clinics may not always be equipped with these tools, underscoring the importance of being prepared and self-reliant, especially during clinical rotations. Moreover, mastering the subtle techniques needed for examining ears and eyes requires extensive repeated practice as part of supervised medical training.

Selecting Your Diagnostic Kit

Given the multitude of diagnostic kit options available, choosing the right one can be a daunting task. For top-notch and dependable tools, we suggest exploring Riester’s diagnostic products. When making your selection, consider the features and components that best suit your needs. 

e-scope®

Black Pocket Otoscope/Ophthalmoscope Set
  • Pocket otoscope/ophthalmoscope set that runs on two AA alkaline batteries (batteries not included)
  • 3.7 V LED technology offers a low-reflection, bright and white light (approx. 5500 K). LED ensures color-neutral illumination in addition to improved color differentiation.
Otoscope
  • 3x magnification and pivotable viewing lens
  • Suitable for performing pneumatic otoscopy
    (see accessories section for information)
Ophthalmoscope
  • Diopter disc with 18 corrective lenses
    (+/- 1, 2, 3, 4, 6, 8, 10, 15, 20 diopters)
  • Aperture wheel with six different apertures
    (fixation star, large circle, small circle, red free filter, blue filter, semi circle)
  • Parallel beam path
  • Dust protected

Frequently Asked Questions

  1. How do I turn my device on/off? There is small, black, circle on/off switch on the side of the device, push the button up towards the head to power on, and push towards the bottom of the handle to power off.
  2. How do I change the bulb in my instrument head? To change the bulb in your instrument head, make sure the device is powered off and then unscrew the head from the handle. In the base of the head you will notice a small nub coming out of the head – this is the base of the bulb, please use your fingers or a set of tweezers if desired to pull the bulb out. To replace the bulb, simply line up the new bulb with the opening at the base of the instrument head and push in.
  3. How do I clean my equipment? To avoid possible cross-contamination, the diagnostic instruments and their handles must be cleaned and disinfected regularly. The diagnostic instruments together with their handles can be cleaned on the outside using a damp cloth (if necessary, moistened with alcohol) until they are visually clean. Wipe with disinfectant (e.g. disinfectant Bacillol AF from Bode Chemie GmbH (time 30s)) only according to the instructions of use of the respective manufacturer of disinfectant. Only disinfectants with proven effectiveness according to national guidelines should be used. After disinfecting, wipe the instruments with a damp cloth to remove potential residue. Please make sure that the cloth is moistened but NOT saturated, so that no moisture penetrates the openings in the diagnostic instrument or its handle. Make sure that glass and lenses are only cleaned with a dry and clean cloth.
  4. What is the warranty of my equipment? Riester EENT traditional sets carry a 2 year warranty on the heads, handles and batteries.

Ordering information

Diagnostic Kits
ART. NO. REGION AVAILABLE DESCRIPTION
2131-203 All e-scope® Pocket Otoscope/Ophthalmoscope Set, black
Accessories
ART. NO. REGION AVAILABLE DESCRIPTION
3703 All ri-scope® L F.O. otoscope L2 LED 2.5 V, C-handle for 2 alkaline batteries type C or ri-accu®
3704 All ri-scope® L F.O. otoscope L3 LED 2.5 V, C-handle for 2 alkaline batteries type C or ri-accu®
14061-531 EU Disposable specula Ø 2.5 mm, pack of 100 pcs.
14061-532 EU Disposable specula Ø 2.0 mm, pack of 100 pcs.
14061-533 EU Disposable specula Ø 3.0 mm, pack of 100 pcs.
14061-534 EU Disposable specula Ø 4.0 mm, pack of 100 pcs.
14061-535 EU Disposable specula Ø 5.0 mm, pack of 100 pcs.
14062-531 EU Disposable specula Ø 2.5 mm, pack of 500 pcs.
14062-532 EU Disposable specula Ø 2.0 mm, pack of 500 pcs.
14062-533 EU Disposable specula Ø 3.0 mm, pack of 500 pcs.
14062-534 EU Disposable specula Ø 4.0 mm, pack of 500 pcs.
14062-535 EU Disposable specula Ø 5.0 mm, pack of 500 pcs.
14063-531 EU Disposable specula Ø 2.5 mm, pack of 1000 pcs.
14063-532 EU Disposable specula Ø 2.0 mm, pack of 1000 pcs.
14063-533 EU Disposable specula Ø 3.0 mm, pack of 1000 pcs.
14063-534 EU Disposable specula Ø 4.0 mm, pack of 1000 pcs.
14063-535 EU Disposable specula Ø 5.0 mm, pack of 1000 pcs.
10961 All Connector for pneumatic test (only needed with e-scope)
10960 All Bulb for pneumatic test (compatible with all Riester otoscopes)

ri-scope®

L2 LED otoscope / L2 LED ophthalmoscope, 2.5 V, C-handle for 2 alkaline batteries type C (batteries not included)
  • This EENT set comes with one C cell handle and two instrument heads, in a case with a sleeve of 10 specula
  • There are two options for powering this set: rechargeable Li-ion batteries or disposable C cell alkaline batteries
 
L2 LED otoscope
  • Fiber optic LED illumination for optimal light beam transmission
  • Bi-directional swiveling lens
    (allowing for easy insertion of instruments)
  • 3x magnification
  • Integrated throat illuminator
  • Suitable for pneumatic test
    (supplied without insufflator bulb - 10960)

 

 

 

 

 
L2 LED ophthalmoscope
  • Parallel beam path - The illuminated retinal area is fully visible – even with narrow pupils. Optimum conditions are achieved for ophthalmological examinations.
  • Dust-proof fully sealed optics
  • Optimized high-performance optics with aspherical condenser lens
  • 29 corrective lenses
    (Plus 1-10, 12, 15, 20, 40 Minus 1-10, 15, 20, 25, 30, 35)

apertures-l-2

Frequently Asked Questions

  1. How do I attach the head to the handle in my student kit? Line up the silver base on the bottom of the instrument head with the silver base of the handle, you will notice notches cut out of the head and some small knobs on the handle. Line the knobs on the handle up with the notches in the head and twist to lock them into place.
  2. How do I turn my device on/off? At the base of the instrument head you will see a black collar with a +/- symbol, twist the collar towards the + symbol to power the device on, and to turn it off twist the collar towards the – symbol. You can also brighten or dim the illumination of the device by utilizing this method. After 180 seconds of no use, the device will power down itself to save the battery life.
  3. How do I know if my device is fully charged? If your device is fully charged, you will see a green light emitting from the collar of the instrument. If the device is low on power, the collar will be emitting an orange light.
    Riester ri-scope L Advanced Desk Set Photo copy
  4. How do I change the bulb in my instrument head? To change the bulb in your instrument head, make sure the device is powered off and then unscrew the head from the handle. In the base of the head you will notice a small nub coming out of the head – this is the base of the bulb, please use your fingers or a set of tweezers if desired to pull the bulb out. To replace the bulb, simply line up the new bulb with the opening at the base of the instrument head and push in.
  5. How do I clean my equipment? To avoid possible cross-contamination, the diagnostic instruments and their handles must be cleaned and disinfected regularly. The diagnostic instruments together with their handles can be cleaned on the outside using a damp cloth (if necessary, moistened with alcohol) until they are visually clean. Wipe with disinfectant (e.g. disinfectant Bacillol AF from Bode Chemie GmbH (time 30s)) only according to the instructions of use of the respective manufacturer of disinfectant. Only disinfectants with proven effectiveness according to national guidelines should be used. After disinfecting, wipe the instruments with a damp cloth to remove potential residue. Please make sure that the cloth is moistened but NOT saturated, so that no moisture penetrates the openings in the diagnostic instrument or its handle. Make sure that glass and lenses are only cleaned with a dry and clean cloth. 
    Never place the instrument heads and handles in liquids. Make sure that no liquids penetrate the housing interior. The device is not approved for machine reprocessing and sterilization. It can lead to irreparable damage!
  6. What is the warranty of my equipment? Riester EENT traditional sets carry a 2 year warranty on the heads, handles and batteries.

Ordering information

Diagnostic Kits
ART. NO. REGION AVAILABLE DESCRIPTION
3704 All ri-scope® L F.O. otoscope L3 LED 2.5 V, C-handle for 2 alkaline batteries type C or ri-accu®
3703 All ri-scope® L F.O. otoscope L2 LED 2.5 V, C-handle for 2 alkaline batteries type C or ri-accu®
3746.013 All ri-scope® L2 LED otoscope / L2 LED ophthalmoscope, 2.5 V, C-handle for 2 alkaline batteries type C, not included
3832 US ri-scope® L2 LED otoscope/L2 LED ophthalmoscope, 3.5V, with battery + charger for US
3833 EU ri-scope® L2 LED otoscope/L2 LED ophthalmoscope, 3.5V, with battery + charger for EU
3834 UK ri-scope® L2 LED otoscope/L2 LED ophthalmoscope, 3.5V, with battery + charger for UK
3835 AU ri-scope® L2 LED otoscope/L2 LED ophthalmoscope, 3.5V, with battery + charger for AU
Accessories
ART. NO. REGION AVAILABLE DESCRIPTION
14061-531 EU Disposable specula Ø 2.5 mm, pack of 100 pcs.
14061-532 EU Disposable specula Ø 2.0 mm, pack of 100 pcs.
14061-533 EU Disposable specula Ø 3.0 mm, pack of 100 pcs.
14061-534 EU Disposable specula Ø 4.0 mm, pack of 100 pcs.
14061-535 EU Disposable specula Ø 5.0 mm, pack of 100 pcs.
14062-531 EU Disposable specula Ø 2.5 mm, pack of 500 pcs.
14062-532 EU Disposable specula Ø 2.0 mm, pack of 500 pcs.
14062-533 EU Disposable specula Ø 3.0 mm, pack of 500 pcs.
14062-534 EU Disposable specula Ø 4.0 mm, pack of 500 pcs.
14062-535 EU Disposable specula Ø 5.0 mm, pack of 500 pcs.
14063-531 EU Disposable specula Ø 2.5 mm, pack of 1000 pcs.
14063-532 EU Disposable specula Ø 2.0 mm, pack of 1000 pcs.
14063-533 EU Disposable specula Ø 3.0 mm, pack of 1000 pcs.
14063-534 EU Disposable specula Ø 4.0 mm, pack of 1000 pcs.
14063-535 EU Disposable specula Ø 5.0 mm, pack of 1000 pcs.
10960 All Bulb for pneumatic test (compatible with all Riester otoscopes)
 

Taylor

The Riester Taylor (or Tomahawk) percussion reflex hammer for assessing myotatic (often patellar and ankle) and cutaneous reflexes is the classic hammer design, featuring a triangular rubber head and flat stainless-steel handle. Lighter than the other versions it is used for myotatic and plantar responses with less effort and greater patient comfort.

percussion-hammer-taylor

Percussion hammer Taylor

Dejerine

The Riester Dejerine percussion reflex hammer for assessing myotatic (often patellar and ankle) reflexes and cutaneous is available with or without a needle to allow the addition of a pinprick test to check two variables: (1) the actual ability to feel a pinprick and (2) the ability to determine the difference between sharp and dull. Manufactured in stainless steel with an ergonomic handle for improved feel and accuracy.

percussion-hammers-dejerine-two

Dejerine 1, left, Dejerine 2, right

Troemner

The Riester Troemner percussion reflex hammer for assessing myotatic (often patellar and ankle) reflexes is a two-headed mallet with both large and small rubber heads. The larger mallet is used to test tendon stretch reflexes, while the smaller mallet is used to test percussion myotonia. Manufactured in stainless steel with an ergonomic handle for improved feel and accuracy.

percussion-hammers-troemner-two

Percussion hammers Troemner

Babinsky

The Riester Babinsky percussion reflex hammer for assessing myotatic (often patellar and ankle) reflexes is similar to the Queen Square hammer in appearance and function in testing the plantar reflex. The chrome, threaded handle can be screwed in from the side or straight for various use scenarios. The rubber head can be easily removed for cleaning.

percussion-hammers-babinsky

Percussion hammer Babinsky

Berliner

The Riester Berliner percussion reflex hammer for assessing myotatic (often patellar and ankle) reflexes features a rubber semi-circle disk is attached to a metal handle bent at a 90-degree angle. Manufactured in stainless steel with an ergonomic handle for improved feel and accuracy.

percussion-hammers-berliner

Percussion hammer Berliner

Queens

The Riester Queens percussion reflex hammer for assessing myotatic (often patellar and ankle) and cutaneous reflexes has a plastic handle with a round metal head and rubber outer ring, the handle tapers to a point to allow for testing the plantar reflex.

percussion-hammers-queens

Percussion hammer Queens

Product details

 

Percussion hammers   
Taylor Handle made of stainless steel, 20 cm
Dejerine Handle made of stainless steel, 21 cm
Handle made of stainless steel with needle 21 cm
Troemner Handle made of stainless steel, 22 cm, 180 g
Handle made of stainless steel, 22 cm, 230 g
Babinsky Handle chrome plated 2 threads on head of hammer to either screw in handle from the side or bottom, 24 cm
Berliner Handle made of stainless steel, 20 cm
Queens Handle made of plastic, 35 cm
Buck Highest quality finish, chrome plated with needle and brush, 18 cm

Riester Blog

Where to buy?

Riester products are available in over 150 countries. Enter your country to easily find an authorized Riester distributor near you.