Features

- Measures Blood Pressure, SpO2, Pulse Rate and Temperature.
- USB and Bluetooth interface connection allows for measurements to be shared to a PC for Telemedicine applications.
- Up to 6000 groups blood pressure data storage.
- Quickly capture temperature measurements results within 5 seconds.
- 4.3” display with lithium battery.
Product Accessories
Accessories Included:
1 adult SpO2 sensor
1 adult NIBP cuff (27-42cm)
1 charger
1 USB data cable
1 thermometer
1 carry case
For use with the Riester telemedicine point of care stations
Seamlessly Integrates with Riester’s Telemedicine stations and Telemedicine software solution partners Docs in Clouds and AMD.
Simultaneously capture and share vital signs data asynchronously or live in Telemedicine consultation.

Point of care stations

Telemedicine Case
The Riester Telemedicine case is designed to allow patient assessments to be carried out in remote locations globally.

Telemedicine Cart
The Riester Telemedicine cart is designed specifically to deliver a stable platform for teleconsultations.
Product details
Spot check vital signs monitor Specifications
Physical Dimensions | 220.98 mm x 175.26 mm x 106.68 mm (8.7” x 6.9” x 4.2”) |
Weight | 1.2 kg (2.65 lb) |
Electrical Operation | Class II protection against electrical shock. |
IP Index | IPX2 |
Classification | Type BF applied part |
Operating Conditions | 5 °C to 40 °C a relative humidity range of 30% to 80%. |
Air pressure | 700 hPa to 1060 hPa |
Storage Conditions | Ambient temperature: -20°C~60°C |
Relative humidity | 10%~95%, non-condensing |
Atmospheric pressure | 53.0kPa~106.0kP |
Oxygen Saturation (SpO2) Specifications
Measuring range: | 35% - 100% |
Accuracy: | ±2% (during 75% - 100%) |
Pulse Rate Specifications
Measuring range | (0 - 300) bpm |
Accuracy | ±2% or ±3% (whichever is greater) |
Blood Pressure Specifications
Range | 0 mmHg - 300 mmHg (0 kPa - 39.9 kPa) |
Pressure transducer accuracy | ±3 mmHg (0.39 kPa) |
Measuring range | Systolic pressure: 60 mmHg - 240 mmHg (7.99 kPa - 31.9 kPa) |
Diastolic pressure | 30 mmHg - 180 mmHg (3.99 kPa - 23.9 kPa) |
Temperature Specifications
Measuring range | 32 °C - 43.89 °C (89.6 F - 111 F) |
Accuracy | ±17.67 °C (during 35 - 38.89 °C) ±18 °C (other) ±0.2 °F (during 95 – 102 °F) ±0.4 °F (other) |
Measuring time | <5 s |
Power Supply
Power | 3.7 V Li-ion battery or 5 V/1.2 A |
Supply voltage | 3.5 - 4.2 V |
Operating current | ≤800 mA |
Ordering information
PC-303 Vital Signs Monitor
Art. No. | Region | Description |
---|---|---|
1965 | All except US | Vital Signs Monitor PC-303 |
Where to buy?
Riester products are available in over 150 countries. Enter your country to find a Riester distribution partner near you.